{"id":3976,"date":"2020-03-06T16:30:00","date_gmt":"2020-03-06T16:30:00","guid":{"rendered":"https:\/\/cortartec.net\/?page_id=3976"},"modified":"2020-09-25T00:25:55","modified_gmt":"2020-09-25T00:25:55","slug":"punching-shear-reinforcement","status":"publish","type":"page","link":"https:\/\/cortartec.net\/en\/products\/structures\/punching-shear-reinforcement\/","title":{"rendered":"Punching Shear Reinforcement"},"content":{"rendered":"[vc_row][vc_column][mk_gallery images=&#8221;1607,1618,1619&#8243; height=&#8221;300&#8243; hover_scenarios=&#8221;none&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_tabs responsive=&#8221;false&#8221; container_bg_color=&#8221;&#8221;][vc_tab title=&#8221;Details&#8221; tab_id=&#8221;1566866031-1-40&#8243;][vc_column_text disable_pattern=&#8221;false&#8221; css=&#8221;.vc_custom_1595413020928{margin-bottom: 0px !important;}&#8221;]<strong>ANTI-PUNCHING ARMOR REINFORCEMENTS<\/strong><\/p>\n<p>The weight of a plate supported on a column induces shear stresses on the slab. These stresses, if sufficient and where no additional reinforcement is provided, would result in the &#8216;drilling&#8217; column through the slab. This perforation cut is similarly induced at the base on which the column rests. Although the drilling cut can be alleviated by the localized thickening of the cement with the supporting beams and extended column heads, the construction of flat plates offers many advantages. A consistent main space can reduce the total height of a building to 3 and can provide significant time and material savings.<\/p>\n<p><strong>Typical arrangements<\/strong><\/p>\n<p>Our Shearfix system is suitable for all speaker shapes and locations. The layout of the Shearfix rails is determined by the design calculation or design program. Some of the typical arrangements are shown here.[\/vc_column_text][vc_column_text css=&#8221;.vc_custom_1595413031599{margin-bottom: 0px !important;}&#8221;]The weight of a support slab on a column induces shear stresses in the slab. These stresses are sufficient, when additional reinforcement is not foreseen, result in &#8220;perforation&#8221; by the column through the slab. This perforation effect is also induced at the base of the column. Although the punching can be alleviated by localized thickening of the cement with hanging beams and attenuated by capitals protruding from the pillars, the construction of flat slabs offers many advantages. Cortartec Shearfix is \u200b\u200bthe ideal solution for the design and construction of problems associated with punching. The system consists of connectors with two heads welded to flat bars and are positioned around the top of the column or at the base. The cutting force of the slab is transferred through the connectors into the column. The connectors are welded to the rail at specific centers or when calculating the design. Cortartec Shearfix is \u200b\u200bsuitable for all forms of columns and it is very easy to install the &#8216;top down&#8217; or &#8216;bottom up&#8217;, depending on the preference on site.[\/vc_column_text][\/vc_tab][vc_tab title=&#8221;Download&#8221; tab_id=&#8221;1566866086439-2-10&#8243;][mk_button dimension=&#8221;flat&#8221; corner_style=&#8221;rounded&#8221; size=&#8221;medium&#8221; url=&#8221;https:\/\/48bfe850-8fa9-41aa-a01f-515ad5db562b.filesusr.com\/ugd\/b0e443_b99048205e744d8ca0ab0ec18f078982.pdf&#8221; align=&#8221;center&#8221;]PDF Catalog[\/mk_button][\/vc_tab][vc_tab title=&#8221;Certificates&#8221; tab_id=&#8221;1566866087001-3-3&#8243;]<div role=\"form\" class=\"wpcf7\" id=\"wpcf7-f9192-o1\" lang=\"pt-PT\" dir=\"ltr\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/en\/wp-json\/wp\/v2\/pages\/3976#wpcf7-f9192-o1\" method=\"post\" class=\"wpcf7-form init\" novalidate=\"novalidate\" data-status=\"init\">\n<div style=\"display: none;\">\n<input type=\"hidden\" name=\"_wpcf7\" value=\"9192\" \/>\n<input type=\"hidden\" name=\"_wpcf7_version\" value=\"5.4.2\" \/>\n<input type=\"hidden\" name=\"_wpcf7_locale\" value=\"pt_PT\" \/>\n<input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f9192-o1\" \/>\n<input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/>\n<input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/>\n<\/div>\n<p>Please request the technical sheet \/ certificates here:<\/p>\n<p><span class=\"wpcf7-form-control-wrap nome\"><input type=\"text\" name=\"nome\" value=\"\" size=\"40\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Name\" \/><\/span><\/p>\n<p><span class=\"wpcf7-form-control-wrap email\"><input type=\"email\" name=\"email\" value=\"\" size=\"40\" class=\"wpcf7-form-control wpcf7-text wpcf7-email wpcf7-validates-as-required wpcf7-validates-as-email\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Email\" \/><\/span><\/p>\n<p><span class=\"wpcf7-form-control-wrap telefone\"><input type=\"tel\" name=\"telefone\" value=\"\" size=\"40\" class=\"wpcf7-form-control wpcf7-text wpcf7-tel wpcf7-validates-as-required wpcf7-validates-as-tel\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Phone\" \/><\/span><\/p>\n<p><span class=\"wpcf7-form-control-wrap empresa\"><input type=\"text\" name=\"empresa\" value=\"\" size=\"40\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" placeholder=\"Company\" \/><\/span><\/p>\n<p><span class=\"wpcf7-form-control-wrap produto\"><input type=\"hidden\" name=\"produto\" value=\"Punching Shear Reinforcement\" size=\"40\" class=\"wpcf7-form-control wpcf7dtx-dynamictext wpcf7-dynamichidden\" aria-invalid=\"false\" \/><\/span><\/p>\n<p><span class=\"wpcf7-form-control-wrap rgpd\"><span class=\"wpcf7-form-control wpcf7-acceptance\"><span class=\"wpcf7-list-item\"><label><input type=\"checkbox\" name=\"rgpd\" value=\"1\" aria-invalid=\"false\" \/><span class=\"wpcf7-list-item-label\">I consent that Cortartec keep my data contained in this form indefinitely until the completion of this contact request.<\/span><\/label><\/span><\/span><\/span><\/p>\n<p><input type=\"submit\" value=\"Request\" class=\"wpcf7-form-control wpcf7-submit\" \/><\/p>\n<p style=\"display: none !important;\" class=\"akismet-fields-container\" data-prefix=\"_wpcf7_ak_\"><label>&#916;<textarea name=\"_wpcf7_ak_hp_textarea\" cols=\"45\" rows=\"8\" maxlength=\"100\"><\/textarea><\/label><input type=\"hidden\" id=\"ak_js_1\" name=\"_wpcf7_ak_js\" value=\"162\"\/><script>document.getElementById( \"ak_js_1\" ).setAttribute( \"value\", ( new Date() ).getTime() );<\/script><\/p><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div><\/form><\/div>[\/vc_tab][\/vc_tabs][\/vc_column][\/vc_row][vc_row][vc_column][mk_fancy_title color=&#8221;#fe6600&#8243; size=&#8221;25&#8243; font_weight=&#8221;bold&#8221; txt_transform=&#8221;uppercase&#8221; margin_bottom=&#8221;0&#8243; font_family=&#8221;none&#8221;]Radial Layouts[\/mk_fancy_title][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/3&#8243;][mk_image src=&#8221;https:\/\/cortartec.net\/wp-content\/uploads\/2019\/11\/imagem3.jpg&#8221; image_width=&#8221;300&#8243; image_height=&#8221;187&#8243; align=&#8221;center&#8221; margin_bottom=&#8221;20&#8243;][\/vc_column][vc_column width=&#8221;1\/3&#8243;][mk_image src=&#8221;https:\/\/cortartec.net\/wp-content\/uploads\/2019\/11\/imagem4.jpg&#8221; image_width=&#8221;300&#8243; image_height=&#8221;168&#8243; align=&#8221;center&#8221; margin_bottom=&#8221;20&#8243;][\/vc_column][vc_column width=&#8221;1\/3&#8243;][mk_image src=&#8221;https:\/\/cortartec.net\/wp-content\/uploads\/2019\/11\/imagem5.jpg&#8221; image_width=&#8221;300&#8243; image_height=&#8221;168&#8243; align=&#8221;center&#8221; margin_bottom=&#8221;20&#8243;][\/vc_column][\/vc_row][vc_row][vc_column][mk_padding_divider size=&#8221;20&#8243;][\/vc_column][\/vc_row][vc_row][vc_column][mk_fancy_title color=&#8221;#fe6600&#8243; size=&#8221;25&#8243; font_weight=&#8221;bold&#8221; txt_transform=&#8221;uppercase&#8221; margin_bottom=&#8221;0&#8243; font_family=&#8221;none&#8221;]Cruciform Layouts[\/mk_fancy_title][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/3&#8243;][mk_image src=&#8221;https:\/\/cortartec.net\/wp-content\/uploads\/2019\/11\/imagem6.jpg&#8221; image_width=&#8221;300&#8243; image_height=&#8221;225&#8243; align=&#8221;center&#8221; margin_bottom=&#8221;20&#8243;][mk_padding_divider size=&#8221;80&#8243;][\/vc_column][vc_column width=&#8221;1\/3&#8243;][mk_image src=&#8221;https:\/\/cortartec.net\/wp-content\/uploads\/2019\/11\/imagem7.jpg&#8221; image_width=&#8221;300&#8243; image_height=&#8221;225&#8243; align=&#8221;center&#8221; margin_bottom=&#8221;20&#8243;][\/vc_column][vc_column width=&#8221;1\/3&#8243;][mk_image src=&#8221;https:\/\/cortartec.net\/wp-content\/uploads\/2019\/11\/imagem8.jpg&#8221; image_width=&#8221;300&#8243; image_height=&#8221;225&#8243; align=&#8221;center&#8221; margin_bottom=&#8221;20&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/4&#8243;][mk_image src=&#8221;https:\/\/cortartec.net\/wp-content\/uploads\/2019\/11\/images-7.jpg&#8221; image_size=&#8221;full&#8221; align=&#8221;center&#8221; margin_bottom=&#8221;20&#8243;][\/vc_column][vc_column width=&#8221;3\/4&#8243;][vc_column_text css=&#8221;.vc_custom_1595413046244{margin-bottom: 0px !important;}&#8221;]<strong>Sizes \/ Settings<\/strong><\/p>\n<p>The Shearfix system consists of double-headed spikes welded to flat rails. It is manufactured to meet the specific needs of each application. The screws are manufactured in five diameters (10, 12, 16, 20 and 25mm) of reinforcement bar approved by CARES B500C. The heads are hot forged to three times the bar diameter. Screws are manufactured in almost any length to suit the depth of the slab, but are usually formed in 5mm increments within the 100-1000mm range. The bar used in this system has a characteristic elastic limit of 500N \/ mm2. The pins are welded to the rail at the centers determined by the design calculation. Shearfix rails are manufactured from steel strips, 16mm wide x 3mm thick on screws up to 16mm in diameter and 20mmx5mm on the two bolt diameters. The rails have rounded ends to reduce the risk of injury during handling. The space between the strips allows the passage of concrete during casting and also allows the rail to allow the rail to be nailed through spacers to the formwork when fixed &#8216;from the bottom up&#8217;, that is, before any other reinforcement.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][mk_padding_divider size=&#8221;80&#8243;][mk_fancy_title color=&#8221;#999999&#8243; size=&#8221;40&#8243; font_weight=&#8221;200&#8243; txt_transform=&#8221;uppercase&#8221; margin_bottom=&#8221;5&#8243; font_family=&#8221;none&#8221; align=&#8221;center&#8221;]SIMILAR <strong>PRODUCTS<\/strong>[\/mk_fancy_title][mk_divider style=&#8221;thin_solid&#8221; divider_width=&#8221;custom_width&#8221; custom_width=&#8221;80&#8243; thin_single_color=&#8221;#fe6600&#8243; thickness=&#8221;4&#8243; margin_top=&#8221;0&#8243; margin_bottom=&#8221;40&#8243;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/4&#8243;][mk_image src=&#8221;https:\/\/cortartec.net\/wp-content\/uploads\/2020\/03\/imagem64.jpg&#8221; image_width=&#8221;300&#8243; image_height=&#8221;225&#8243; link=&#8221;https:\/\/cortartec.net\/en\/products\/structures\/tension-compression-systems\/&#8221; align=&#8221;center&#8221; margin_bottom=&#8221;20&#8243;][mk_fancy_title color=&#8221;#fe6600&#8243; size=&#8221;25&#8243; font_weight=&#8221;bold&#8221; txt_transform=&#8221;uppercase&#8221; margin_bottom=&#8221;0&#8243; font_family=&#8221;none&#8221;]Tension &amp; Compression Systems[\/mk_fancy_title][mk_padding_divider size=&#8221;30&#8243; visibility=&#8221;visible-sm&#8221;][\/vc_column][vc_column width=&#8221;1\/4&#8243;][mk_image src=&#8221;https:\/\/cortartec.net\/wp-content\/uploads\/2020\/03\/imagem18.jpg&#8221; image_width=&#8221;300&#8243; image_height=&#8221;225&#8243; link=&#8221;https:\/\/cortartec.net\/en\/products\/structures\/reinforcement-continuity-systems\/&#8221; align=&#8221;center&#8221; margin_bottom=&#8221;20&#8243;][mk_fancy_title color=&#8221;#fe6600&#8243; size=&#8221;25&#8243; font_weight=&#8221;bold&#8221; txt_transform=&#8221;uppercase&#8221; margin_bottom=&#8221;0&#8243; font_family=&#8221;none&#8221;]Reinforcement Continuity Systems[\/mk_fancy_title][mk_padding_divider size=&#8221;30&#8243; visibility=&#8221;visible-sm&#8221;][\/vc_column][vc_column width=&#8221;1\/4&#8243;][mk_image src=&#8221;https:\/\/cortartec.net\/wp-content\/uploads\/2020\/03\/transferir.jpg&#8221; image_width=&#8221;300&#8243; image_height=&#8221;225&#8243; link=&#8221;https:\/\/cortartec.net\/en\/products\/structures\/reinforcing-bar-couplers\/&#8221; align=&#8221;center&#8221; margin_bottom=&#8221;20&#8243;][mk_fancy_title color=&#8221;#fe6600&#8243; size=&#8221;25&#8243; font_weight=&#8221;bold&#8221; txt_transform=&#8221;uppercase&#8221; margin_bottom=&#8221;0&#8243; font_family=&#8221;none&#8221;]Reinforcing Bar Couplers[\/mk_fancy_title][mk_padding_divider size=&#8221;30&#8243; visibility=&#8221;visible-sm&#8221;][\/vc_column][vc_column width=&#8221;1\/4&#8243;][mk_image src=&#8221;https:\/\/cortartec.net\/wp-content\/uploads\/2020\/03\/imagem20.jpg&#8221; image_width=&#8221;300&#8243; image_height=&#8221;225&#8243; link=&#8221;https:\/\/cortartec.net\/en\/products\/structures\/insulated-balcony-connectors\/&#8221; align=&#8221;center&#8221; margin_bottom=&#8221;20&#8243;][mk_fancy_title color=&#8221;#fe6600&#8243; size=&#8221;25&#8243; font_weight=&#8221;bold&#8221; txt_transform=&#8221;uppercase&#8221; margin_bottom=&#8221;0&#8243; font_family=&#8221;none&#8221;]Insulated Balcony Connectors[\/mk_fancy_title][\/vc_column][\/vc_row][vc_row fullwidth=&#8221;true&#8221; fullwidth_content=&#8221;false&#8221; css=&#8221;.vc_custom_1597843161068{margin-top: 50px !important;padding-top: 30px !important;background-color: #fe6600 !important;}&#8221;][vc_column width=&#8221;2\/3&#8243;][mk_fancy_title tag_name=&#8221;h5&#8243; color=&#8221;#ffffff&#8221; size=&#8221;26&#8243; font_weight=&#8221;400&#8243; txt_transform=&#8221;none&#8221; margin_top=&#8221;10&#8243; font_family=&#8221;none&#8221;]Have questions? We are here to help you![\/mk_fancy_title][\/vc_column][vc_column width=&#8221;1\/3&#8243;][mk_button dimension=&#8221;flat&#8221; corner_style=&#8221;rounded&#8221; size=&#8221;large&#8221; url=&#8221;https:\/\/cortartec.net\/en\/contacts\/&#8221; align=&#8221;right&#8221; margin_right=&#8221;0&#8243; el_class=&#8221;mrightButton&#8221; bg_color=&#8221;#f0f0f0&#8243; btn_hover_bg=&#8221;#ffffff&#8221; text_color=&#8221;dark&#8221; btn_hover_txt_color=&#8221;#fe6600&#8243;]CONTACT US[\/mk_button][\/vc_column][\/vc_row]\n","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][mk_gallery images=&#8221;1607,1618,1619&#8243; height=&#8221;300&#8243; hover_scenarios=&#8221;none&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_tabs responsive=&#8221;false&#8221; container_bg_color=&#8221;&#8221;][vc_tab title=&#8221;Details&#8221; tab_id=&#8221;1566866031-1-40&#8243;][vc_column_text disable_pattern=&#8221;false&#8221; css=&#8221;.vc_custom_1595413020928{margin-bottom: 0px !important;}&#8221;]ANTI-PUNCHING ARMOR REINFORCEMENTS The weight of a plate supported on a column induces shear stresses on the slab. These stresses, if sufficient and where no additional reinforcement is provided, would result in the &#8216;drilling&#8217; column through the slab. This perforation cut is similarly induced [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":0,"parent":2707,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v19.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Punching Shear Reinforcement - Cortartec<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/cortartec.net\/en\/products\/structures\/punching-shear-reinforcement\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Punching Shear Reinforcement - Cortartec\" \/>\n<meta property=\"og:description\" content=\"[vc_row][vc_column][mk_gallery images=&#8221;1607,1618,1619&#8243; height=&#8221;300&#8243; hover_scenarios=&#8221;none&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_tabs responsive=&#8221;false&#8221; container_bg_color=&#8221;&#8221;][vc_tab title=&#8221;Details&#8221; tab_id=&#8221;1566866031-1-40&#8243;][vc_column_text disable_pattern=&#8221;false&#8221; css=&#8221;.vc_custom_1595413020928{margin-bottom: 0px !important;}&#8221;]ANTI-PUNCHING ARMOR REINFORCEMENTS The weight of a plate supported on a column induces shear stresses on the slab. These stresses, if sufficient and where no additional reinforcement is provided, would result in the &#8216;drilling&#8217; column through the slab. This perforation cut is similarly induced [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/cortartec.net\/en\/products\/structures\/punching-shear-reinforcement\/\" \/>\n<meta property=\"og:site_name\" content=\"Cortartec\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/facebook.com\/cortartec\" \/>\n<meta property=\"article:modified_time\" content=\"2020-09-25T00:25:55+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@cortartec\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Organization\",\"@id\":\"https:\/\/cortartec.net\/fr\/#organization\",\"name\":\"Cortartec\",\"url\":\"https:\/\/cortartec.net\/fr\/\",\"sameAs\":[\"https:\/\/instagram.com\/cortartec\",\"https:\/\/za.linkedin.com\/company\/cortartec?trk=recent-update_see-all\",\"https:\/\/pinterest.com\/cortartec\",\"https:\/\/youtube.com\/user\/cortartec\",\"https:\/\/facebook.com\/cortartec\",\"https:\/\/twitter.com\/cortartec\"],\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/cortartec.net\/fr\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/cortartec.net\/wp-content\/uploads\/2019\/08\/logo.png\",\"contentUrl\":\"https:\/\/cortartec.net\/wp-content\/uploads\/2019\/08\/logo.png\",\"width\":400,\"height\":100,\"caption\":\"Cortartec\"},\"image\":{\"@id\":\"https:\/\/cortartec.net\/fr\/#\/schema\/logo\/image\/\"}},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/cortartec.net\/fr\/#website\",\"url\":\"https:\/\/cortartec.net\/fr\/\",\"name\":\"Cortartec\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/cortartec.net\/fr\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/cortartec.net\/fr\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/cortartec.net\/en\/products\/structures\/punching-shear-reinforcement\/\",\"url\":\"https:\/\/cortartec.net\/en\/products\/structures\/punching-shear-reinforcement\/\",\"name\":\"Punching Shear Reinforcement - Cortartec\",\"isPartOf\":{\"@id\":\"https:\/\/cortartec.net\/fr\/#website\"},\"datePublished\":\"2020-03-06T16:30:00+00:00\",\"dateModified\":\"2020-09-25T00:25:55+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/cortartec.net\/en\/products\/structures\/punching-shear-reinforcement\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/cortartec.net\/en\/products\/structures\/punching-shear-reinforcement\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/cortartec.net\/en\/products\/structures\/punching-shear-reinforcement\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"In\u00edcio\",\"item\":\"https:\/\/cortartec.net\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/cortartec.net\/en\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Structures\",\"item\":\"https:\/\/cortartec.net\/en\/products\/structures\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Punching Shear Reinforcement\"}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Punching Shear Reinforcement - Cortartec","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/cortartec.net\/en\/products\/structures\/punching-shear-reinforcement\/","og_locale":"en_US","og_type":"article","og_title":"Punching Shear Reinforcement - Cortartec","og_description":"[vc_row][vc_column][mk_gallery images=&#8221;1607,1618,1619&#8243; height=&#8221;300&#8243; hover_scenarios=&#8221;none&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_tabs responsive=&#8221;false&#8221; container_bg_color=&#8221;&#8221;][vc_tab title=&#8221;Details&#8221; tab_id=&#8221;1566866031-1-40&#8243;][vc_column_text disable_pattern=&#8221;false&#8221; css=&#8221;.vc_custom_1595413020928{margin-bottom: 0px !important;}&#8221;]ANTI-PUNCHING ARMOR REINFORCEMENTS The weight of a plate supported on a column induces shear stresses on the slab. These stresses, if sufficient and where no additional reinforcement is provided, would result in the &#8216;drilling&#8217; column through the slab. This perforation cut is similarly induced [&hellip;]","og_url":"https:\/\/cortartec.net\/en\/products\/structures\/punching-shear-reinforcement\/","og_site_name":"Cortartec","article_publisher":"https:\/\/facebook.com\/cortartec","article_modified_time":"2020-09-25T00:25:55+00:00","twitter_card":"summary_large_image","twitter_site":"@cortartec","twitter_misc":{"Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Organization","@id":"https:\/\/cortartec.net\/fr\/#organization","name":"Cortartec","url":"https:\/\/cortartec.net\/fr\/","sameAs":["https:\/\/instagram.com\/cortartec","https:\/\/za.linkedin.com\/company\/cortartec?trk=recent-update_see-all","https:\/\/pinterest.com\/cortartec","https:\/\/youtube.com\/user\/cortartec","https:\/\/facebook.com\/cortartec","https:\/\/twitter.com\/cortartec"],"logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/cortartec.net\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/cortartec.net\/wp-content\/uploads\/2019\/08\/logo.png","contentUrl":"https:\/\/cortartec.net\/wp-content\/uploads\/2019\/08\/logo.png","width":400,"height":100,"caption":"Cortartec"},"image":{"@id":"https:\/\/cortartec.net\/fr\/#\/schema\/logo\/image\/"}},{"@type":"WebSite","@id":"https:\/\/cortartec.net\/fr\/#website","url":"https:\/\/cortartec.net\/fr\/","name":"Cortartec","description":"","publisher":{"@id":"https:\/\/cortartec.net\/fr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/cortartec.net\/fr\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/cortartec.net\/en\/products\/structures\/punching-shear-reinforcement\/","url":"https:\/\/cortartec.net\/en\/products\/structures\/punching-shear-reinforcement\/","name":"Punching Shear Reinforcement - Cortartec","isPartOf":{"@id":"https:\/\/cortartec.net\/fr\/#website"},"datePublished":"2020-03-06T16:30:00+00:00","dateModified":"2020-09-25T00:25:55+00:00","breadcrumb":{"@id":"https:\/\/cortartec.net\/en\/products\/structures\/punching-shear-reinforcement\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/cortartec.net\/en\/products\/structures\/punching-shear-reinforcement\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/cortartec.net\/en\/products\/structures\/punching-shear-reinforcement\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"In\u00edcio","item":"https:\/\/cortartec.net\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/cortartec.net\/en\/products\/"},{"@type":"ListItem","position":3,"name":"Structures","item":"https:\/\/cortartec.net\/en\/products\/structures\/"},{"@type":"ListItem","position":4,"name":"Punching Shear Reinforcement"}]}]}},"_links":{"self":[{"href":"https:\/\/cortartec.net\/en\/wp-json\/wp\/v2\/pages\/3976"}],"collection":[{"href":"https:\/\/cortartec.net\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/cortartec.net\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/cortartec.net\/en\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/cortartec.net\/en\/wp-json\/wp\/v2\/comments?post=3976"}],"version-history":[{"count":0,"href":"https:\/\/cortartec.net\/en\/wp-json\/wp\/v2\/pages\/3976\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/cortartec.net\/en\/wp-json\/wp\/v2\/pages\/2707"}],"wp:attachment":[{"href":"https:\/\/cortartec.net\/en\/wp-json\/wp\/v2\/media?parent=3976"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}